Cavity Wall Insulation Cost Irving

Is it time for Cost Attic Insulation in Irving? What is the best type to choose? Let us focus on four specific types. One is blown attic insulation the other is batt insulation. Each type has pros and cons. However, which is the best choice for you.

Spray In Foam Insulation

One of the best advantages of blown attic insulation over batt is that the blown style covers everything; while there can be open areas in the batt type.

Loose Fill Insulation

When you’re looking to have your home or building insulated with spray foam insulation, you have a couple of product choices. Whether you go with closed foam or open foam insulation, the differences in their make will make a big difference in which one will work best for your needs.

Radiant barrier insulation has one reflective side that is made from an aluminum coating. Any radiant barrier insulation can be installed in an existing or new home. The reflective side of the barrier insulation is made to face the open air pocket of the surface.

Almost all Cost Attic Insulation in Irving are tested and rated as fireproof. If for some strange reason you find one that is not, stay away from that product.

Loft Insulation Offers

Spray Foam Insulation Basics

Although spray foam insulation as we know it today truly emerged in the 1980s, spray foam actually has its roots several decades further in the past, beginning with the development of polyurethane foam in the 1940s by Otto Bayer.

Otto Bayer, an industrial chemist, actually began working with polyurethane in Germany during the late 1930s. This technology was brought to the United States in the early 1940s by David Eynon, the president of Mobay, a war effort conglomerate created from the partnering of two chemical industry giants, Monsanto and the Bayer Corporation. Although Otto Bayer worked for Bayer Corporation, he was not related to the company's founding family.

During the 1940s, polyurethane polymers were used primarily in military and aviation applications. The production of war machines for the World War II conflict drove most of the applications of these high-grade plastic polymers for the duration of the war.

It was not until the 1950s that polyurethane began to be used in home insulation. It was the invention of the "Blendometer" that allowed for expansion of polyurethane application to the home insulation realm. The Blendometer was the first machine able to mix components for the creation of polyurethane foam and was created by Walter Baughman in 1953.

The 1980s and early 1990s saw a great deal of controversy within the spray foam insulation industry as different marketing schemes from various companies promoted the benefits of closed verses open foam insulation and as some companies tried to market water blown foam application processes.

Though there has been much debate within the industry, R-value standards, used as a measure of determining energy efficiency, have cleared up much of the controversy. R-value ratings clearly define closed foam as the most effective means of making a home as energy efficient as possible.

Closed cell spray foam has additionally been added to the list of building requirements for making homes in hurricane and earthquake zones more structurally sound. The improved stability of homes insulated with spray foam technology makes the use of spray foam a smart move for any homeowner regardless of geographic location. 

Radiant Barrier Foil

Heat Transfer, R-Value, and Spray Foam Insulation

Adding insulation to your attic is a great way to save energy, but there are a number of choices that you need to sort through. What is the best type for your situation? What is the best location for this added insulation? How much should you add?

The first thing that you need to determine is how much insulation you already have. Measure the depth and determine the type. Then multiply the depth by the appropriate value: Cellulose: 3.1, Fiberglass Batt or Blown: 3.7, Closed-Cell Foam: 6.2, Open-Cell Foam: 3.6.

Before you move any further to insulate your attic, you should make sure that you have any knob and tube wiring in your attic that would be covered by insulation replaced. The wires in this type of system need to be in the open air in order to dissipate heat. If they are surrounded by insulation this will trap the heat and cause a fire hazard.

Once you have calculated the R-value of your insulation, you need to determine how much more you should add. Energy Starr has developed recommended levels of attic insulation for every Zone throughout the US. See map at Energy Star and chart below. However, what it boils down to is most houses don't have enough insulation. R-30 is the bare minimum and unless you live in south Florida, the recommended amount is twice that.

Radiant Barriers: work differently than thermal insulation. They reflect the heat away from the thermal insulation, instead of slowing the heat transfer through it. This effectively increases the performance of your thermal insulation in your attic by 50% to 70%. Radiant barriers work best if they are installed between the attic insulation and the roof sheathing, and when they are sloped so that dust will not accumulate on it as quickly. Furthermore, radiant barriers are fairly inexpensive and easy to install.

Your last step is to determine if you are going to add thermal insulation, a radiant barrier, or both. If your house already has what is the code minimum in many locations of R-30, adding a radiant barrier should boost its effectiveness to 45 or even 50. Or if you have an old house with 5 ½" of fiberglass or cellulose (R-17 to R-20) and you add another R-19 and a radiant barrier, you effective insulation value should be between 54 and 65.


Roof Insulation Cost Texas